Product catalogue
Explore equipment families, model series and technical configurations for transmission, distribution and industry.
Oil-immersed transformers
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| S11S11 distribution transformers | 10 kV / 30–2,500 kVA | Oil-immersed distribution transformers selected around the required capacity, voltage ratio, connection group and site conditions. |
| S13S13 distribution transformers | 10 kV / 30–2,500 kVA | An oil-immersed distribution series for projects with defined load profiles, loss requirements and installation conditions. |
| S20S20 distribution transformers | 10 kV / 30–2,500 kVA | Distribution transformers with capacity, tapping, impedance and cooling requirements coordinated against the project specification. |
| S22S22 distribution transformers | 10 kV / 30–2,500 kVA | An oil-immersed distribution option for projects specifying rated capacity, voltage ratio and load and no-load loss requirements. |
| S22 / SZ22 (35 kV)35 kV power transformers | 35 kV / up to 31.5 MVA | 35 kV power transformer configurations, with tapping, cooling, impedance and insulation requirements defined for the project. |
| 35–500 kVLarge power transformers | 35–500 kV | Oil-immersed power transformers for high-voltage projects. Capacity, cooling, tapping and site interfaces are specified for each application. |
Dry-type transformers
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| SCB10–SCB18SCB dry-type transformer range | 10 kV / 30–2,500 kVA | Cast-resin dry-type transformers for distribution applications, with enclosure, cooling and temperature-monitoring requirements specified for the installation. |
| SC12 (35 kV)35 kV dry-type transformers | 35 kV / 800–25,000 kVA | Higher-capacity dry-type transformers for projects requiring dry insulation, with installation clearances, cooling and enclosure conditions reviewed together. |
Compact substations
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| YBPrefabricated substations | 12 / 0.4 kV / 100–1,600 kVA | MV switching, transformer and LV distribution integrated into a substation package, with layout, protection, metering and environment requirements coordinated together. |
High-voltage switchgear
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| GISGas-insulated switchgear | 35–550 kV product range | Gas-insulated switching equipment for high-voltage substations, selected against the single-line diagram, bus arrangement and project duty. |
| HGISHybrid gas-insulated switchgear | Project-specific voltage and configuration | Hybrid switching arrangements coordinated with the substation layout, switching duty, insulation requirements and equipment interfaces. |
| GILGas-insulated transmission lines | 220 kV and above | Gas-insulated transmission solutions with route, current duty, insulation coordination and terminal connections assessed against the project design. |
Switchgear & automation
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| DFWCable distribution boxes | Cable distribution and branching | Cable distribution enclosures configured around the circuit arrangement, cable terminations, installation location and access requirements. |
| KYN28-12 / KYN28A-12Metal-clad MV switchgear | 12 kV model families | Metal-clad switchgear assemblies with circuit-breaker selection, protection, metering and interlocking defined by the electrical design. |
| XGN2-12 / HXGN-12Fixed and ring-main switchgear | Fixed / ring-main configurations | Switchgear options for distribution circuits, with switching functions, cable interfaces, protection and site layout specified for the project. |
| MNS / GCSWithdrawable LV switchgear | Withdrawable low-voltage assemblies | Low-voltage distribution assemblies with withdrawable functional units, arranged around the load schedule, protection and operating requirements. |
| GGD / XL-21Fixed LV distribution cabinets | Fixed low-voltage distribution | Fixed distribution cabinets with outgoing circuits, protective devices, metering and installation interfaces coordinated with the project drawings. |
| GGJReactive-power compensation cabinets | Reactive-power compensation | Compensation cabinets sized against the load profile, power-factor target, harmonic conditions and switching strategy. |
| JPOutdoor integrated distribution boxes | Outdoor distribution assemblies | Outdoor distribution boxes with circuit, metering, protection and compensation functions coordinated for the transformer installation. |
Electrical enclosures
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| Control enclosuresElectrical cabinet enclosures | Fabrication to approved drawings | Metal enclosures with dimensions, material, mounting points, doors, openings and surface finish defined in the approved drawings. |
| Dry-type transformer enclosuresDry-type transformer enclosures | Project-specific dimensions and ventilation | Transformer enclosures coordinated with equipment dimensions, ventilation clearances, cable entry, maintenance access and installation conditions. |
PLC control cabinets
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| PLC / S7-1200 / HMIPLC control cabinets | PLC control and HMI integration | PLC cabinets with S7-1200 and HMI configurations matched to the approved I/O list, control sequence, communication and equipment interfaces. |
Variable-frequency drive cabinets
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| VFDVariable-frequency drive cabinets | Variable-frequency motor control | Drive cabinets selected around motor ratings, load characteristics, speed-control requirements, protection, cooling and control interfaces. |
Substation enclosures
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| Substation enclosuresSubstation enclosures | Layout and environmental requirements | Substation housings with compartments, access doors, ventilation, lifting points and equipment interfaces coordinated against the approved layout. |
EV charging equipment
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| TATS700-160-S120 kW dual-connector EV chargers | 120 kW / two connectors / equal power sharing | Integrated dual-connector charging equipment with 120 kW total rated power and equal power sharing. Connection and project requirements are confirmed separately. |
| TATS500-12060 kW single-connector EV chargers | 60 kW / one connector | Integrated single-connector charging equipment rated at 60 kW. Electrical connection, installation and site requirements are coordinated for each project. |
UPS systems
Product details| Series / model | Rating / configuration | Equipment description |
|---|---|---|
| UPS integrationUPS system integration | Project-specific load and autonomy | UPS integration based on load in kVA/kW, required backup time, battery configuration, bypass arrangements and distribution interfaces. |
No matching equipment. Try another search or contact us with your specification.