Power transformers 66–500 kV

Power transformers for 66–500 kV projects, together with application-specific furnace, rectifier and traction transformers and GIS packages. Electrical ratings, equipment configuration and acceptance requirements are confirmed for each project.

Request a project quotation
66–500 kV

66–500 kV power transformers

Manufactured in Tai'an, China. Kestvan handles the project specification, technical interfaces and delivery scope.

Power transformers: 66–500 kV

Project enquiries can cover power transformers at 66–500 kV. Rated capacity, winding voltages, connection group, impedance, cooling, tap regulation and guaranteed losses are established in the technical agreement for the proposed design. The voltage range does not imply that every configuration is available on identical terms.

Furnace, rectifier and traction transformers

Special-transformer enquiries are reviewed against the process or traction-system duty. Load cycles, harmonics, current profile, overload requirements and converter or furnace interfaces form the specification basis. Voltage, capacity, winding arrangement and cooling are reviewed individually rather than inferred from the power-transformer range.

GIS equipment and project interfaces

GIS supply is assessed against the single-line diagram, bus arrangement, operating voltage, fault duty, protection and metering. Insulating medium, gas-management requirements, site interfaces and destination rules are part of the technical review. Voltage range and configuration are confirmed for the specific GIS proposal.

Technical coordination and defined supply scope

The project schedule identifies the equipment, interconnections, accessories, documentation, inspection points and delivery responsibilities included in the offer. Existing distribution-product tables and certificate previews do not establish the ratings or certification scope of these high-voltage packages. Design-specific evidence is reviewed separately.

Project inputs for technical review

  • Project application, country, grid requirements and specified standard editions.
  • Single-line diagram, rated capacity, winding voltages, phases and frequency.
  • Connection group, neutral/earthing arrangement, impedance and network short-circuit data.
  • Load profile, duty cycles, harmonics and process-specific overload requirements.
  • Cooling requirements, ambient conditions, altitude, noise and installation constraints.
  • Tap range, regulation method and required operating or monitoring functions.
  • Protection, metering, auxiliary supply, cable/terminal and GIS interface requirements.
  • Inspection and test scope, witness points, programme, packing and delivery requirements.

Technical documents to agree

  • Project technical schedule, approved drawings and an explicit list of deviations and supply exclusions.
  • Delivered-unit routine records linked to serial numbers, with applicable test conditions and acceptance criteria agreed.
  • Relevant type- and special-test evidence: model, design relevance, scope and any additional testing agreed after technical review.
  • GIS equipment, insulating-medium and interface documentation where included in the confirmed package.
  • Packing and transport information, operation and maintenance instructions, and the agreed site-handover document pack.

Distribution references and certificate scope

The existing distribution-transformer reference tables and certificates for their stated manufacturing scope are not a performance or certification guarantee for these high-voltage products. The offered configuration, applicable standards, inspection plan and design-relevant test documents are reviewed for each project.

Before requesting a quotation

Does the 66–500 kV range also apply to GIS and special transformers?

No. This stated range applies to power transformers. Furnace, rectifier and traction transformers and GIS are assessed separately; their voltages, capacities and configurations are confirmed against the project requirements.

Do the distribution-product certificates cover these high-voltage packages?

They do not automatically apply. The offered equipment's model, design and required routine, type and special-test evidence are reviewed separately, with scope and acceptance requirements recorded in the technical agreement.

Product selection and enquiry

When to use this product

Use the 66–500 kV range for power-transformer project screening. Furnace, rectifier and traction transformers and GIS are assessed against their own duty and interfaces.

What to send for a quotation

Send the destination specification, single-line diagram, MVA, winding voltages, impedance, tap range, cooling, loss limits and test scope. For a special transformer, add duty cycles, harmonics and overload requirements.

Check the project documents

Technical knowledgeExplore the guidesPrepare your project
WhatsAppRequest a quotation